Installation instructions, only for experts
5.4. Connecting the fan (optional)
1. Guide the fan cable through the cable bushing
for 230 V/400 V
2. Connect the fan cable to the terminal strip
nection diagram. Observe the operating instructions for the respective device.
5.5. Connecting the additional output (optional)
The additional output can, for example, be used for an infrared lamp or infrared
heat plates.
WARNING!
Risk of fi re
The additional output has no excess temperature fuse. For this reason
only intrinsically safe devices should be used on the additional output.
● If infrared heaters are connected to the additional output, these must
have an excess temperature fuse.
● If infrared heat plates are connected to the additional output, the foil
sensor P-ISX-FF must be used and activated when starting up the sauna
for the fi rst time (see 8.6. Activating/deactivating the foil sensor on
page 29).
1. Guide the connection cable for the additional device through the cable bush-
ing
into the connection area for 230 V/400 V
8
2. Connect the power supply cables to the terminal strip
with the connection diagram. Observe the operating instructions and safety
instructions for the respective device.
5.6. Connecting the power booster (optional)
1. Guide the cable for the power booster through the cable bushing
the connection area for 230 V/400 V
2. Connect the cable for the power booster to the terminal strip
ance with the connection diagram. To do so, use terminal "ST1" for the safety
circuit, and terminal "ST2" for the control circuit. Observe the operating
instructions for the respective device.