Installation instructions, only for experts
8. Starting-up
The function selection switch in the
low-voltage connection area allows
a variety of product functions to be
activated. The figure at the right
shows the standard setting for the
function selection switch.
8.1. Setting the fan operating mode
The fan can either be regulated or switched on and off. The dimmer switch func-
tion is activated or deactivated using the function selection switch 1.
● The function selection switch 1 is set to the ON position as standard. The
dimmer switch function is therefore activated.
● If you wish to deactivate the fan dimmer switch, place the function selection
switch 1 in the OFF position.
8.2. Activating single-sensor mode
In single-sensor mode, the sauna control unit is only operated with the heater
sensor with excess temperature fuse (F1 sensor). The single-sensor mode must
be activated using the function selection switch 2.
WORLD OF WELLNESS
OFF
Fig. 6 Function selection switch
– Standard setting
p. 27/44
EN