Battery Mode; Battery Records - Cristec BAT-MON-3.5 Manuel Utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5.1
B
ATTERY MODE
The mode "Not synchronized" appears when the shunt is restarted and the displayed capacity value does not yet correspond
to the true capacity level. Then the battery connected to the shunt must be fully charged with a battery charger, so that the
capacity indicator can synchronize with the state of charge of the battery. The message then goes off automatically.

Battery records

5.1.1
Battery history (available for shunt #1 only)
5.1.2
By pressing the chart symbol, the battery usage is graphically displayed.
(3h), the last 3 days (3d) and the last 30 days (30d).
History
Resolution
3 hours
45 seconds
3 days
18 minutes
30 days
2
See terms and definition in section 5.3
3
Records are lost if the display power supply is switched-off
See section 5.1.1
See section 5.2.2
After pressing the circle in Battery mode the specifics battery details are shown:
Battery
Capacity
Time remaining
Mode
Temperature
Battery (+2)
By pressing the magnifying glass icon more detailed historic information about
the battery are shown:
Charging cycles
Deep discharges
Lost capacity
Discharge rate
The min/max values are determined from a 45 seconds interval to get an idea
about the use of the battery
Max. Charge / Max. charge and discharge currents
Lowest / Highest voltage (+1 lead mesurement)
Lowest / Highest temperature (when external sensor is connected)
Content
Capacity, mean voltage and average current over the last 3 hours.
Capacity, mean voltage and average current over the last 3 days.
Minimum / maximum capacity and minimum / maximum voltage over
3 hours
the last 30 days
Main battery (+1) name, voltage and current
Actual capacity in percent (%)
2
Expected remaining time until the capacity alarm
triggers,or expected charging time during charging
Charge, discharge or Not synchronized
Battery temperature when external sensor is connected
Additional battery (+2) name and voltage
2
Number of charging cycles
2
Number of deep discharges
2
The lost (not useable) capacity (%)
2
Average discharge rate
3
:
You can access information
3
about the last 3 hours