When Relay control is Capacity, following settings are available:
1
2
3
Note : When pulse mode is selected the Gen set has to
be stopped manually.
When Relay control is Voltage, following settings are available:
1
2
3
Note : Pulse mode is not available in Voltage control.
4.3
S
- B
HUNT
ATTERY
M
ODE
1: Capacity On Level
When mode is Passive (N.O.), relay is active when
actual capacity of channel selected falls under this
level
2: Capacity Off Level
When mode is Passive (N.O.), relay is inactive when
actual capacity of channel selected rises over this
level
3: Channel
Select the trigger source (shunt)
1: Undervoltage
When mode is Passive (N.O.), relay is active when
voltage +1 of channel selected falls below this level.
Relay is inactive when actual voltage rises above this
level (+0.6V hysteresis)
2: Overvoltage
When mode is Passive (N.O.), relay is active when
voltage +1 of channel selected rises above this level.
Relay is inactive when actual voltage falls below this
level (-0.6V hysteresis)
3: Channel
Select the trigger source (shunt)
31