In Battery mode, the gauge indicates the current state of charge of the battery. The icon of the source and the current that is
currently flowing are also displayed. A minus sign before the amperes value indicates that the battery is being discharged. If
the current is positive, the battery is charged. Following alarms may occur:
Logo
Permanent
In Energy mode only the symbol of the source and the actual current appear.
By pressing the circle more details about the monitored battery / energy source will appear.
M
ODE
Figure 5 : Shunt #1 with additional battery (+2) and shunt #2 in Energy Mode
Color
Alarm
Orange
Battery capacity below the user capacity level (see section 4.3)
Blinking
Red
Critical state of charge
Blinking
Red
Deep discharge
Red
Battery voltage above overvoltage level (see section 4.3)
Blinking
Red
Battery voltage under undervoltage level (see section 4.3)
Blinking
Data
Comment
Name
This name is associated to a logo
displayed on the main page
Device
Serial number of the shunt,
software and hardware version.
Info
Reset Ah
The total ampere hour (Ah)
counter value for the source can
counter
be read and reset.
: battery capacity below the 20% level
: battery capacity is 0%
Range
Alternator, Solar,
Hydro, Wind
-
-