If - with the compressor switched off - air is lost at the pressure control valve, proceed as
follows:
a) Completely empty the compressed air tank.
b) Remove plug N (fig. 4) from the 'retainer' valve.
c) Carefully clean valve base and seal, and reassemble.
Overload switch of the compressor is actuated:
a) Push in the overload switch (fig. 5)
b) Completely unroll the cable from its roller
When switching over from 'flushing air + water' to 'compressed air – compressor' pressure is not
reduced at the compressor inlet. The compressor will not start.
We recommend that you let off pressure from the boiler.
ATTENTION:
c) If possible, do not disassemble fittings while tank is under pressure. Always ensure that it is
discharged.
d) While the plug is in the socket, the cover of the pressure control may not be removed.
5.1

Accessories

The relevant accessories and an order form can be found from Page 82 onwards.
6.

Disposal

Components of the unit are recyclable material and should be put to recycling. For this purpose
registered and certified recycling companies are available. For an environmental-friendly
disposal of the non-recyclable parts (e.g. electronic waste) please contact your local waste
disposal authority.