Table 206 - Recommended separation distances between portable and mobile RF communications equipment and
visocor OM40
®
visocor OM40 is intended for use in an electromagnetic environment in which radiated RF disturbances are monitored. The customer or the user of
®
OM40 can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmit-
ters) and
visocor OM40 as recommended below, according to the maximum output power of the communications equipment.
®
Rated maximum output power of
Separation distance according to frequency of transmitter
transmitter
150 kHz to 80 MHz
W
N/A
0.01
N/A
0.1
N/A
1
N/A
10
N/A
100
N/A
For transmitters rated at a maximum output power not listed above, the recommended separation distance d in metres (m) can be estimated using the
equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter
manufacturer.
NOTE 1 To calculate the recommended separation distance of transmitters in the frequency range of 80 MHz and 800 MHz to 2.5 GHz, an additional factor of
10/3 has been used in order to reduce the probability of a mobile/portable communications device unintentionally introduced into the patient area causing
a fault.
NOTE 2 These guidelines may not apply in all situations. Propagation of electromagnetic waves is affected by absorption and reflection by structures, objects and
people.
GB-60
Appendix
visocor
®
m
80 MHz to 800 MHz
800 MHz to 2.5 GHz
d=1.2√P
d=1.2√P
0.12
0.23
0.38
0.73
1.2
2.3
3.8
7.3
12
23
Appendix
Warranty
The device was manufactured and tested with the
utmost care. If it should nevertheless have defects, we
give a warranty on the following terms:
1. During the term of the warranty of 2 years as of the
date of purchase we agree to remedy such defects,
at our discretion and at our expense, by repair (after
the product has been returned to our factory) or in
the form of a replacement by a non-defective device.
2. The warranty does not cover normal use of wearing
parts or any damage which arises as a result of
non-observance of the Instructions for Use, improper
handling (e.g. unsuitable power sources, breakage,
leaking batteries) and/or dismantling of the device
by the purchaser. In addition, the warranty does not
cover compensation claims filed with us.
3. Warranty claims can only be filed during the term of
the warranty by presenting the receipt. In the event
of a warranty claim the device must be returned to
the following address, together with the receipt and
description of complaint: UEBE Medical GmbH,
Service-Center, Zum Schlag 18, 97877 Wertheim,
Germany.
4. The purchaser's contractual defect rights vis-a-vis
the seller in accordance with § 437 of the German
Civil Code are not restricted by the warranty.
Important:
In the event of a warranty claim please always
include the receipt.
GB-61
G