Setting low voltage exit lights
This menu makes to possible to set the flashing exit function.
no
FLSh
Not used
WL
Flasher operation (fixed frequency)
Indicator light operation: Indicates the status of the gate in
real-time. The type of blinking indicates the four possible
conditions:
- GATE STOPPED: Light off
- GATE IN PAUSE: the light is on, fixed
- GATE OPENING: the light blinks slowly (2 Hz)
- GATE CLOSING: the light blinks quickly (4 Hz)
Blinker during pause time
Blinker usually operates during the gate motion only; however, if this
function is enabled, blinker will be on during the pause time too
(gate open with automatic closure active).
The flasher may be either in the device connected to the
CiCL
(setting the
parameter in the
to the low voltage output (setting the
menu).
Start input function
This menu allows selecting input operation modes (see paragraph
"Activation inputs"):
StAn
Start and Pedestrian Start input standard operation, according
to menu setups.
no
Start inputs from terminal board are disabled.
Radio inputs operate in standard mode.
AP.CH
Start impulse always controls the opening phase, Pedestrian
Start always controls the closing phase.
PrES
Manned operation; the gate will open as long as the Start
input stays closed and it will close as long as Pedestrian
Start stays closed.
oroL
Timer-operation; the gate stays open while the Start input or
Pedestrian Start input is closed; as soon as the contact
opens, the pause count down will start.
70
LUCI
output
LUCi
menu) or the device connected
FLSh
SPiA
parameter in the