V2 SPA Zariss Manuel De L'installateur page 66

Actionneur électromécanique irréversible avec bras articulé pour portails battants
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Gate leaf delay during closing
During closing, the SUPERIOR gate leaf starts to move after the
INFERIOR gate leaf, with a delay equal to the length of time set by this
menu.
Lock time
Before the opening phase begins, the control unit will energize the
electric lock in order to release it and enable the gate motion.
t.SEr
time will fix the energizing time.
no
WARNING: in case the gate has no electric lock,
set the value 0 (
will appear on display).
Silent Locking Mode
This menu allows you to select the silent operation mode for the electric
lock.
Si
Silent Mode (100 Hz)
no
Standard Mode (50 Hz)
CAUTION: In silent mode, the voltage supplied to the lock
has a higher frequency in order to make the locking less noisy.
In some cases, there may be problems when unlocking.
If problems should occur, select the Standard mode.
Lock advance time
While the electric lock is energized, the gate will stay standstill for
time, to make its release easier.
t.ASE
t.SEr
In case
is lower than
the doors will start moving.
WARNING: in case the gate has no electric lock,
set the value 0
Backlash time
It could be useful to give a closing command to motors, to help the
electric lock release.
The control unit controls the motors in reduced power in closing
direction for the setup time.
The backlash precedes the electric lock release. It is possible to reverse
the order by setting a lock advance time higher then the backlash one.
WARNING: in case the gate has no electric lock,
set the value 0.
64
, the lock energizing will go on while
t.ASE

Publicité

Table des Matières
loading

Table des Matières