3.4 - MOTOR UNBLOCKING

In the case of a power failure, the gate can be unblocked
by operating the motor:
1. Open the lock cover J located on the front of the motor
2. Insert the key L into the hole and turn clockwise until
reaching the end-stop
To reset the automation device, proceed as follows:
1. Turn the key L anti-clockwise until reaching the end
stop and then extract it
2. Close the lock using the cover J
3.5 - FIXING THE OPENING
MECHANICAL STOP
1. Release the motor reducer
2. Open the leaf/door to its maximum opening position
3. Position stop M in close contact with the arm
4. Tighten the screws N
5. Loosen the screws fixing the straight arm to the motor
reducer
6. Position the casing D on the straight arm and tighten
the screw E after having inserted the washer