10 - WORKING TIME SELF-TRAINING
This menu allows automatic learning of the times required for the gate to open and close.
During this phase, the control unit also records the forces required to open and close the gate: these values will be used by activating the
obstacle sensor.
1. Press and hold the OK key until the display shows -APP
2. Release the OK key: the display shows ESC (only press the OK key if it is desired to exit this menu)
key: the display shows t.LAu
3. Press the
4. Press the OK key to activate the working time self-training cycle: the display shows the control panel and starts the time self-training
procedure.
PLEASE NOTE:
• If self-training is performed during the initialisation procedure, the sensitivity value acquired for the obstacle sensor is
automatically saved in the memory, hence the procedure terminates at step 4.5
• If there is only one motor present, the procedure starts at step 4.3
4.1
Gate leaf 1 is opened for a few seconds
4.2
Gate leaf 2 is closed until one of the following conditions occurs:
- the obstacle sensor detects the gate leaf is blocked
- a START command is given
4.3
Gate leaf 1 is closed until one of the following conditions indicated in part 4.2 occurs
This position is stored as the closing point for gate leaf 1.
4.4
An opening manoeuvre is performed for each gate leaf, the operation terminates when one of the conditions described in part
4.2 occurs (the first START stops gate leaf 1, the second START stops gate leaf 2).
The time required is stored as the opening time.
4.5
A closing manoeuvre is performed for each gate leaf; the operation terminates when one of the conditions indicated in part 4.2
occurs. The time required is stored as the closing time.
5. The display shows the value recommended for the obstacle sensor for motor 1. If no operations are performed for 20 seconds, the
control unit exits the programming phase, without saving the value recommended.
6. The recommended value may be modified by pressing the
display shows SEn1
key: the display shows SEn2; press the OK key to display the value recommended for the obstacle sensor for motor 2,
7. Press the
which can be modified in a manner similar to that for SEn1
key until the display shows FinE, then press the OK key, select the option Si and then press the OK key to exit
8. Press and hold the
programming mode, storing the value for the sensors.
PLEASE NOTE: If the control unit is left to time out from programming mode (1 minute), the obstacle sensors return to
the value that was set prior to performing self-training (according to the default values, the sensors are disabled). On the
other hand, the opening/closing times are always stored.
and
keys, and pressing the OK key confirms the displayed value and the
60