Operational Logic; Exiting Rapid Configuration - V2 SPA Zariss Manuel De L'installateur

Actionneur électromécanique irréversible avec bras articulé pour portails battants
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

8.3 - OPERATIONAL LOGIC

This rapid configuration option is used to define the start command action (from the terminal board, from the remote control or from the
keypad)
The possible options are:
P - P
Step Logic - the Start command results in opening, stop, closure, stop, in sequence.
AUto
Automatic logic - the Start command is used to open the gate.
- During opening, other Start commands are ignored. Closure is automatic after a programmable pause time
- During the pause, a Start command restarts the pause time count from the beginning.
- During closure, a Start command immediately reopens the gate.
PLEASE NOTE: If automatic logic is selected, the pause time adjustment option is accessed (up to 20 minutes,
the default value is 15 seconds).
PErS
Customised logic: the Start command acts in accordance with the programming of the various Programming Menu parameters.
Selecting the PErS options exits the menu, maintaining the previously set values.

8.4 - EXITING RAPID CONFIGURATION

This menu closes programming (both predefined and customised), saving the modified data in the memory
PLEASE NOTE: if the menu is exited due to time out (after 1 minute without pressing any keys) the data set is not stored.
58

Publicité

Table des Matières
loading

Table des Matières