Mounting the control
Mount the control beside the cabin door, at a height of about 1.70 meters, or in accordance with the recommen-
dations of the cabin manufacturer.
A non-detachable supply connection provides the electrical power supply. The quality of the power supply cable
is at least H07RN-F.
CAUTION - Damages of Device:
The control is splash-proof (degree of protection: IP X4). Nevertheless the control should not come in direct
contact with water.
Mount the control at a dry location.
Environmental conditions of 40° Celsius and a maximum of 95 percent air humidity can not be exceeded.
1.
Pull off the knob 3.
2.
Slightly push in the safety lock 8 and remove the housing cover.
3.
Screw-in the recessed head screw at a height of about 1.80 meters, keeping a maximum distance to the
sauna wall of 7 mm (refer to detail).
4.
Hook the bottom of the housing 1 in location 2 on the mounted recessed head screw.
5.
Screw two recessed head screws, 20 mm in length, into the bottom mounting holes.A
Check for secure fit of the bottom of the housing 1.
CAUTION - Damages of Device:
You are only allowed to use the control K1-2 for controlling 3 heating circuits with a maximum heating capacity of
3.0 kW per heating circuit.
Run the stove sensor lines and door switch lines separate to other power cables in the connection range for extra-
low voltage 4 of the control .
6.
Guide the stove sensor lines through the mounting openings 7 (connection range for extra-low voltage
4) into the bottom of the housing 1 and in accordance with the circuit diagram, connect to the terminal 5.
1
Continued
7.
Applies to optional door switch only:
Guide the door switch lines through the mounting openings 7 (connection range for extra-low voltage 4)
into the bottom of the housing 1 and in accordance with the circuit diagram, connect to the terminal 5.
8.
Guide the supply, heating, and lighting circuits through the mounting openings 9 (connection range for
230 V / 400 V C) into the bottom of the housing 1 and in accordance with the circuit diagram, connect
to the terminal B.
9.
Clamp the protective conductors to the protective-conductor terminal 6.
10.Remove three switches E from the housing cover. When doing so, push out the switches E with a blunt object,
starting from the inside of the housing.
11.
Place the housing cover 1 on top of the bottom of the housing, rotate it to the bottom and push until you
hear it lock.
Check for secure fit of the control.
12.
Attach the three switches E.
13.
Attach the knob 3 (pay attention to the decline at the shaft).