3.5
Make sure that the voltage and capacity of the power line conform to the data shown on the plate
located on the back of the appliance; a copy is attached to the manual.
A second plate, including detailed information about the model and serial number, is placed inside
the equipment on the left side and is visible on opening the oven door.
These plates must never be removed.
Prepare an omni-polar cutoff device on the power supply line of the appliance with a contact
opening distance equal to or more than 3 mm, located in a convenient position near the appliance.
Do not use reducers, adapters or shunts.
Before making the electric connection, make sure of the efficiency of the earthing.
Make sure that the relief valve and the home wiring system are able to withstand the appliance
load.
The yellow/green earth cable must not be subject to cutoffs.
The electric cable must not come into contact with parts whose temperature is more than 50°C
higher than room temperature.
3.5.1
According to the type of power supply, use a cable that conforms to the following table.
Running at 400V3N~ (models connected according to DIAGRAM
"A"): use a pentapolar cable type H05RR-F (cable measuring 5 x
2.5 mm
Running at 230V3~ (models connected according to DIAGRAM
"C" but commutated by the installer according to DIAGRAM
"B"): use a tetrapolar cable type H05RR-F (cable measuring 4 x 4
mm
Running at 230V1N~ (models connected according to DIAGRAM
"C"): up to 2.9 kW use a tripolar cable type H05RR-F (cable
measuring 3 x 1.5 mm
cable type H05RR-F (cable measuring 3 x 2.5 mm
kW and 7 kW use a tripolar cable type H05RR-F (cable measuring
3 x 4 mm
measuring 3 x 6 mm
The end to be connected to the appliance must have the earth wire
(yellow-green) at least 20 mm longer.
74
Instructions for the installer

Electric connection

Electric power cable section
2
).
2
).
2
); between 2.9 kW and 5.4 kW use a tripolar
2
); over 7 kW use a tripolar cable type H05RR-F (cable
2
).
2
); between 5.4