Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

S19-2350
EFX120/P/RS
ASSE 1071 & UPC Certified
®
Inlet Connections: 1-1/4" NPT
Outlet Connection: 1-1/2" NPT
Temperature Range: 65 - 90°F
Maximum Pressure: 125 PSI
Inlet Temperature Hot: 120 - 180° F
Inlet Temperature Cold: 33 - 80° F
Minimum Temperature Differential
(from valve set point): 20° F
Flow at 30 psi: 72.5 GPM
Minimum Cold Water Bypass at 30 psid: 30.0 GPM
Minimum Flow: 3.0 GPM
Maximum Flow with Cold Water Shut-Off: 1.0 GPM
215-1818 Rev. B; ECN 17-09-009
© 2017 Bradley
Page 1 of 25
12/7/2017
Installation
EFX 120/S19-2350
Thermostatic Mixing Valve
with Optional Cabinet
Robinet thermostatique mélangeur
avec armoire en option
Válvula mezcladora termostática con
armario opcional
Table of Contents
Sommaire
Tabla de contenidos
Raccords d'arrivée : 1-1/4 po NPT
Raccord de sortie : 1-1/2 po NPT
Plage de température : 65 - 90 °F
Pression maximum : 125 lb/po
2
Température d'arrivée, eau chaude : 120 - 180 °F
Température d'arrivée, eau froide : 33 - 80 °F
Différence de température minimum
(à partir de valeur de consigne de robinet) : 20 °F
Débit à 30 psi : 72,5 GPM
Dérivation d'eau froide minimum à 30 psid : 30,0 GPM
Débit minimum : 3,0 GPM
Débit maximum avec arrêt d'eau froide : 1,0 GPM
Pre-Installation Information .............................................................2
Supplies Required .......................................................................... 3
Installation Instructions ................................................................... 3
Dimensions..................................................................................... 4
Optional Equipment Installation ..................................................... 6
Troubleshooting .............................................................................. 7
Parts Breakdown .............................................................................8
Avant l'installation ..........................................................................10
Fournitures requises .................................................................... 11
Instructions relatives à l'installation .............................................. 11
Dimensions................................................................................... 12
Installation de l'équipement optionnel .......................................... 14
Dépannage ................................................................................... 15
Liste des pièces ............................................................................17
Información previa a la instalación ................................................18
Materiales necesarios .................................................................. 19
Instrucciones de instalación ......................................................... 19
Dimensiones................................................................................. 20
Instalaciones de equipos opcionales ........................................... 22
Solución de problemas ................................................................. 23
Desglose de piezas .......................................................................25
Conexiones de entrada: NPT de 1-1/4 pulg.
Conexión de salida: NPT de 1-1/2 pulg.
Rango de temperaturas: 65 - 90 °F
Presión máxima: 125 PSI
Temperatura de entrada, caliente: 120 - 180 °F
Temperatura de entrada, fría: 33 - 80 °F
Diferencial de temperatura mínima
(desde el punto de ajuste de la válvula): 20 °F
Flujo a 2,1 bar: 274 L/min
Derivación mínima de agua fría a 2,1 bar: 108 L/min
Flujo mínimo: 11,4 L/min
Flujo máximo con retención de agua fría: 3,8 L/min
Menomonee Falls, WI 53052 USA
800 BRADLEY (800 272 3539)
+1 262 251 6000
bradleycorp.com
P.O. Box 309

Publicité

Table des Matières
loading

Sommaire des Matières pour Bradley EFX 120/S19-2350

  • Page 1: Table Des Matières

    Flujo máximo con retención de agua fría: 3,8 L/min P.O. Box 309 215-1818 Rev. B; ECN 17-09-009 Menomonee Falls, WI 53052 USA © 2017 Bradley 800 BRADLEY (800 272 3539) +1 262 251 6000 Page 1 of 25 12/7/2017 bradleycorp.com...
  • Page 2: Important

    Separate parts from packaging and make sure all parts are accounted for before discarding packaging material. If any parts are missing, do not begin installation until you obtain the missing parts. Product warranties may be found under “Products” on our web site at bradleycorp.com. Bradley • 215-1818 Rev. B; ECN 17-09-009 12/7/2017...
  • Page 3: Supplies Required

    4. Insert the valve into the bracket in the cabinet procedure. (right side of the valve goes in first). Continue with the valve installation procedure. 6. Position the wall flange tight to the wall and caulk in place. Bradley • 215-1818 Rev. B; ECN 17-09-009 12/7/2017...
  • Page 4: Dimensions

    0.47 Dia. Holes 5-1/8" 9-3/4" (6) Places (130) (248) 1-1/4" NPT Inlets 5-5/8" 10-1/2" (143) 2-3/4" (267) (70) 2-3/4" (70) 6-1/2" 24" (165) (610) 9-3/16" (233) 24" 20" 2" 2" (610) (508) (51) (51) Bradley • 215-1818 Rev. B; ECN 17-09-009 12/7/2017...
  • Page 5 Shut the cold water supply off by closing the cold water inlet valve or supply check valve. While the cold water supply is off, check to make sure that the hot water flow has shut down. If hot water is shut down, reopen cold water supply. Test unit weekly for proper function and desired set temperature. Bradley • 215-1818 Rev. B; ECN 17-09-009 12/7/2017...
  • Page 6: Optional Equipment Installation

    7. Let the system run for 30 minutes or longer without water. If, after thirty minutes, the water temperature increases, you may readjust the temperature by slowly closing the balancing valve until the appropriate temperature is reached. Bradley • 215-1818 Rev. B; ECN 17-09-009 12/7/2017...
  • Page 7: Troubleshooting

    Do not remove the seat. The components may be scraped with a screwdriver to remove debris. A pair of tweezers works well for pulling debris out from the seat. If the stop and checks need to be replaced, contact your Bradley representative and ask for Check/Stop Kit (S65-212).
  • Page 8 Chamber and consistently. If it is not consistent, repeat Procedure C until it moves freely, or replace. Contact your Bradley representative and ask for Piston/Liner Kit (part number S65-422). Bradley • 215-1818 Rev. B; ECN 17-09-009 12/7/2017...
  • Page 9: Parts Breakdown

    Mixing Valve Cap Spring O-Ring O-Ring Screw Holder (for Seal) Liner O-Ring O-Ring Seal Spring O-Ring Control Cap Washer Hex Nut Set Screw O-Ring Spring Seal Screw Seat Piston Limit Cover O-Ring O-Ring Pushrod Bradley • 215-1818 Rev. B; ECN 17-09-009 12/7/2017...
  • Page 10: Avant L'installation

    Le cas échéant, ne pas commencer l’installation avant d’avoir obtenu les pièces manquantes. Les garanties du produit se trouvent sous la rubrique « Products » (Produits) sur notre site Web à bradleycorp.com Bradley • 215-1818 Rev. B; ECN 17-09-009 12/7/2017...
  • Page 11: Fournitures Requises

    Continuer avec la procédure (le côté droit du robinet entre en premier). d’installation du robinet. Continuer avec la procédure d’installation du robinet. 6. Positionner la rosace murale tout contre le mur et colmater en place. Bradley • 215-1818 Rev. B; ECN 17-09-009 12/7/2017...
  • Page 12: Armoire Encastrée En Option

    Trous (6) 5-1/8" 9-3/4" Emplacements (130) (248) 5-5/8" 1-1/4" NPT 10-1/2" (143) Entrées 2-3/4" (267) (70) 2-3/4" (70) 6-1/2" 24" (165) (610) 9-3/16" (233) 24" 20" 2" 2" (610) (508) (51) (51) Bradley • 215-1818 Rev. B; ECN 17-09-009 12/7/2017...
  • Page 13: Connecter Les Conduites D'alimentation Et Installer Le Thermostat

    Si l’eau chaude est arrêtée, rouvrir l’alimentation d’eau froide. Tester l’unité chaque semaine pour s’assurer d’un bon fonctionnement et d’un réglage de température désiré. Bradley • 215-1818 Rev. B; ECN 17-09-009 12/7/2017...
  • Page 14: Configuration De Recirculation D'eau Optionnelle

    7. Laisser le système fonctionner pendant 30 minutes ou plus sans eau. Si, après 30 minutes, la température de l’eau augmente, vous pour pouvez rajuster la température en fermant lentement le robinet d’équilibrage jusqu’à ce que la température appropriée soit atteinte. Bradley • 215-1818 Rev. B; ECN 17-09-009 12/7/2017...
  • Page 15: Dépannage

    Remplacer les joints NPT et/ou joints toriques le cas échéant. Pour tout système endommagés. remplacement de joints toriques, contacter le représentant Bradley et lui demander un Kit de joint torique (référence S65-423). Aucun débit d’eau chaude Le thermostat est défectueux et donc le dispositif d’arrêt Vérifier le thermostat :...
  • Page 16: Dépannage : Démontage Du Piston Et Nettoyage

    Si non constant, répéter la Procédure C jusqu’à satisfaction, ou remplacer. Contacter votre représentant Bradley et lui demander un Kit de Piston/Revêtement (référence S65-422). Bradley • 215-1818 Rev. B; ECN 17-09-009 12/7/2017...
  • Page 17: Liste Des Pièces

    Joint torique Joint torique Joint Ressort Joint torique Capuchon de Rondelle Écrou hex commande Joint torique Écrou Ressort Joint torique Vis calante Siège Piston Joint Joint torique Poussoir Joint torique Couverture limite Bradley • 215-1818 Rev. B; ECN 17-09-009 12/7/2017...
  • Page 18: Información Previa A La Instalación

    Saque las piezas del embalaje y asegúrese de haberlas sacado todas antes de desecharlo. Si falta alguna pieza, no comience la instalación hasta obtenerla. Las garantías del producto se pueden encontrar en la sección “Products” (Productos) del sitio Web, bradleycorp.com. Bradley • 215-1818 Rev. B; ECN 17-09-009 12/7/2017...
  • Page 19: Materiales Necesarios

    Continúe con el procedimiento de instalación de la válvula. 6. Ponga firmemente la brida de pared en la pared y aplique masilla para fijarla en su lugar. Bradley • 215-1818 Rev. B; ECN 17-09-009 12/7/2017...
  • Page 20: Dimensiones

    9-3/4" (6) lugares (130) (248) 5-5/8" 10-1/2" Entradas de NPT (143) de 1-1/4" 2-3/4" (267) (70) 2-3/4" (70) 6-1/2" 24" (165) (610) 9-3/16" (233) 24" 20" 2" 2" (610) (508) (51) (51) Bradley • 215-1818 Rev. B; ECN 17-09-009 12/7/2017...
  • Page 21: Ajuste La Temperatura Con El Agua Corriendo

    Si se detiene el agua caliente, vuelva a abrir el suministro de agua fría. Revise la unidad semanalmente para verificar el funcionamiento apropiado y el ajuste deseado de la temperatura. Bradley • 215-1818 Rev. B; ECN 17-09-009 12/7/2017...
  • Page 22: Instalaciones De Equipos Opcionales

    7. Deje que el sistema funcione sin agua durante 30 minutos o más. Si, después de treinta minutos, aumenta la temperatura del agua, puede volver a ajustar la temperatura cerrando lentamente la válvula de equilibrio hasta que se alcance la temperatura adecuada. Bradley • 215-1818 Rev. B; ECN 17-09-009 12/7/2017...
  • Page 23: Solución De Problemas

    Bradley y consulte por el kit (S65-423) de sellos de juntas tóricas. No fluye agua caliente (fluye Falló el termostato y, en consecuencia, se enganchó la Inspección del termostato:...
  • Page 24 Si es constante, repita el Procedimiento C hasta que se mueva libremente o cámbielo. Comuníquese con el representante local de Bradley y consulte por el Kit del pistón y revestimientos (número de pieza S65-422). Bradley • 215-1818 Rev. B; ECN 17-09-009...
  • Page 25: Desglose De Piezas

    Junta tórica Junta tórica Arandela Tapa de control Tuerca de maleficio Junta tórica Tuerca Tornillo de ajuste Resorte Sello Asiento Pistón Tornillo Junta tórica Junta tórica Cubierta de límite Varilla de empuje Bradley • 215-1818 Rev. B; ECN 17-09-009 12/7/2017...

Table des Matières