Electronically Controlled Fryer
The electronic series comes in a gas version and an electric version; it differs from the analogical
series only for its temperature regulator, which is an electronic card in place of a thermostat.
PROVISIONS FOR INSTALLATION
Place (fig.7 – pag.5)
It is advisable to install the appliance in a well ventilated room or under an extractor hood. The
appliance may be installed as a single unit or together with others. In both cases, if it is installed
near a wall of inflammable material, a minimum distance of 100mm from the side and back walls
must be observed. In the event that it is not possible to observe this distance, protective measures
must be taken (e.g. use of sheets of refractory material) which ensure that the temperature of the
walls is within the established safety limits.
Installation
Installation operations, gas or voltage conversions to other than the original, starting up the
installation or appliance, ventilation, letting out fumes, and maintenance must be done following the
manufacturer's instructions and observing the norms in force, by qualified personnel, in compliance
with the following provisions (GB):
ƒ Gas Safety (Installation and Use) Regulations, 1984
ƒ Health and Safety at Work Act, 1974
ƒ Codes of Practice, BS6173, 1982
ƒ The Building Regulations, 1985
ƒ The Building Standards Regulations, 1981
For others countries follow the relevant local rules for:
ƒ Gas board rules
ƒ Building regulations and local fire prevention provisions
ƒ Safety norms in force
ƒ Provisions of the Gas supplying company
ƒ The Electrical Norms in force
ƒ The Fire Brigade rules
Fumes evacuation
These appliances are Type "A" and it is not necessary to connect this type of appliance directly to
an evacuation pipe for combustion products. The products of combustion, however, must be
directed into suitable hoods or similar devices, connected to a reliably efficient chimney, otherwise
directly outside (fig 8, 9, 10 – pag. 5). If this is not possible, the use of an extractor fan connected
directly to the external environment with a capacity no lower than what is stated in table 1 (pag.41)
is acceptable. This value must be increased by the air exchange necessary for the well-being of the