Barre palpeuse mécanique sans fil
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

2 - Make sure screw on steel cable clamp is tightened securely using force (fig. 15).
3 - Make sure lever presses the central limit switch. If it does not, loosen locknut that locks
the adjuster and regulate the adjuster until the castor reaches the proper position (fig.
16).
4 - Unscrew fastening screws of lower cover and remove it (fig. 2 - part. 2).
5 - Marks position (S) on upper side of fastening slot on the side of the aluminum bar (fig.
2 - part. 3).
6 - Position TOUCH Wi-Fi on the wall and mark the position corresponding to the reference
marked previously. In cases of vertical assembly, keep a minimum distance from the
ground of 30 mm and aim the device as shown in fig. 2 - part. 2.
7 - Perforate strip support surface about 7 mm under reference mark and fasten retention
spring with appropriate elements: screws for metal or screws and anchor bolts for
masonry (fig. 2 - part. 4).
8 - Position TOUCH Wi-Fi on retention spring and hook it by pulling it downward.
9 - Mark fastening holes on wall in correspondence to -C- and -D- (fig. 2 - part 1 and 2).
10 - Remove device and drill fastening holes marked previously.
11 - Hook device to spring again and tighten screws.
9
11
13
Regulation check nut
Position the roller on central micro-switch pin
Position the roller on central micro-switch pin
17
G
B
10
12
14
15
16

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Acg3016

Table des Matières