KM2500: general connections (exterior control panel)
The connection of the operator to the VIVO-T101 control panel is shown as an example. Check the control
board instructions.
P1 P2 P3
P4 P5 P6
P15 P14 P16
P7 P8
ST1
FT1
ST2
FT2
FCA1
FCC1
STOP
Turning direction:
Press PUL1 and PUL2 to check the turning direction of the operator. If it is not correct,
interchange the operator cables connected in cable connectors V and W.
VIVO-T101
P11 P12
P22 P23
G7 G8
G9 G10
Courtesy
24Vac
Lamp.
LOCK
Light
All models: clutch adjustment
G1
G2
G3
N
L
POWER
MOTOR1 (G2-G1-COM)
1 Introduce the Allen key (1) in the housing (2).
2 Turn the Allen key until the notches (3) and (4) face
each other.
3 Introduce a screwdriver in the notches (3) and (4) in
order to immobilise the transmission and adjust the
clutch by turning the key (1). Turning clockwise
increases the power, whilst turning anticlockwise
decreases it.
Adjust the torque to respect the maximum
closing
thrusts
EN12453:2000. Make the measurements as
described in Standard EN 12445:2000.
4 If the control panel has torque adjustment (PM), set it
to the maximum.