Turning direction:
Press PUL1 (close) and PUL2 (open) to
check the turning direction of the
o p e r a t o r . I f i t i s n o t c o r r e c t ,
interchange the operator cables
connected in cable connectors RL1
and RL2.
12
KM1800: general connections (AP606 control panel)
DIP7, DIP8, DIP10:
For the correct operation of the
system, ensure DIP7, DIP8 and DIP10
are in OFF position.
KM1800: SW2 functions during programming (DIP1=ON)
DIP1=ON: programming enabled (DL3 lights up)
DIP1=ON and DIP2=ON: total open/close programming
DIP1=ON and DIP3=ON: pedestrian open/close programming
DIP1=ON and DIP4=ON: total opening radio code programming
DIP1=ON and DIP6=ON: pedestrian opening radio code programming
(photocells without testing)
(photocells with testing)
P160Z
Photocell testing:
Opening photocells (SG.A): place DIP6
in ON to enable testing.
Closing photocells (SG.C): place DIP9
in ON to enable testing.