5.4.2-7
5.4.2-8
5.4.2-9
50
All manuals and user guides at all-guides.com
Operations
Step 6:
Minimization completed (Figure 5.4.2-7):
• Exit Minimization Mode.
Minimization to be continued (Figure 5.4.2-8):
• Rotate the wheel until "888" is displayed.
• Double mark the tire at the 12 o'clock position.
• Remove the wheel from the unit.
• Use a tire changer to rotate the tire so that the
double mark is in line with the valve.
• Mount the wheel on the balancer.
• Select the "F" key.
Step 7 (Figure 5.4.2-2):
• Rotate the valve to the 12 o'clock position.
• Select the "F" key.
Step 8 (Figure 5.4.2-3):
• Spin the wheel.
Step 9 (Figure 5.4.2-9):
The unit will display the result:
- - -
EEE Minimization failed.
5.4.2
Default weight setting: ounces.
Select this mode to change the unit of measurement
for the weight, before or after spinning the wheel.
• Hold down the "F" key and press the "Gr/Oz" key.
Repeat the procedure to switch back to ounces.
5.4.3
Default diameter and width unit of measurement:
inches.
• Hold down the "F" key and press the "mm-inch"
key
Repeat the procedure to switch back to inches.
Operator's Manual
Minimization successfully completed
Weight Unit Toggle Mode.
Dimensions Unit Toggle Mode.