Télécharger Imprimer la page

Tube Preparation; Assembly; Wiring; Commissioning - SOMFY OXIMO 40 AUTO io Notice

Publicité

Les langues disponibles

Les langues disponibles

2.1.2. Tube preparation

1) Cut the roller tube to the required length, depending on the
motorised product.
2) Deburr the roller tube and remove the swarf.
3) For roller tubes which are smooth inside, cut a notch with
d
e
Ø 40 x 1
6 mm
8.5 mm
Ø 40 x 1.5
7 mm
8.5 mm
2.1.3. Drive/tube assembly
1) Slide the drive into the roller tube.
For roller tubes which are smooth inside, position the notch
previously cut on the boss on the crown.
2) Fix the roller tube on the drive wheel using the screws or
pop rivets depending on the length (L1).
The screws or pop rivets must only be attached to the
drive wheel and not to the drive.
2.1.4. Installing the drive/tube assembly
onto the drive bracket g
Ensure that the drive/tube assembly is secured onto
the end bracket. This operation prevents the drive/tube
assembly from coming out of the end bracket mounting.
2.1.5. Assembling the electronic part
Never cut the aerial.
The adhesive supplied is only to be used for this operation. Always use the adhesive supplied
by Somfy. The use of any other adhesive is forbidden.
such as a rilsan collar, along with some adhesive. The
additional means of attachment chosen must hold the
electronic part inside the end piece regardless of the
conditions of use of the roller shutter.
Clean the inner face of the head rail end piece (C).
1)
2)
part (B).
3)
Pass the power supply cable through a cable grommet as
it exits the head rail to ensure it is not under strain.
Copyright © 2014 Somfy SAS. All rights reserved.
EN
1)
2)
3)
e
d
1)
2)
L1
f and
f
g
1)
2)
B
C
3)
B
C
23
Images not contractually binding
EN

2.2. WIRING

Cables which pass through a metal wall must be protected and insulated using a sheath or
sleeve.
Attach cables to prevent any contact with moving parts.
The cable on the OXIMO 40 AUTO io cannot be removed. If it is damaged, return the drive to
the After-Sales department.
If the drive is used outdoors, and if the supply cable is a type H05-VVF cable, the cable should
be installed in a UV-resistant duct, e.g. under a gland.
Always make a loop in the power supply cable to prevent water entering the drive!
-
Switch off the power supply.
-
Wire
230V
50Hz
Blue
Neutral (N)
Brown
Live (L)
Earth ( )

2.3. COMMISSIONING

These instructions describe commissioning using a Somfy io-homecontrol
as the Smoove io.
Only one drive should be supplied at a time
A
B
Switch on and follow the procedure
or
A
the control point has been programmed.
24
Images not contractually binding
N
L
OFF
®
local control point such
ON
Programming the
1st Somfy io local
control point
1)
2)
PROG