Airwell AW-FWDB018-N91 Manuel D'installation page 10

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3.2 Select the installation location for the outdoor unit
Please install on the location that meets the following conditions and has the permission
from user.
1. Somewhere that the noise and airflow from the discharge does not affect neighbors.
2. Good ventilation, make sure the outdoor unit has good ventilation.
3. Meet related requirements of environmental protection and cityscape and firefighting.
4. No obstructions to hinder the inlet and outlet of the outdoor unit.
5. Installation location should be able to withstand the weight of the outdoor unit and its vibration, in
order to avoid noise and vibration enlarging in the transmission. Also it should be safe for
installation construction. The mounting surface must be reinforced concrete structures or
equivalent structures. The material and structure design and manufacture of mounting bracket
should fully consider the load-bearing strength, corrosion resistance, and it should be convenient
for fixing. Iron/steel components should be securely welded or connected and rust treated. The
loading capacity of outdoor unit mounting surface (mounting bracket) should not less than at least
200 kg.
6. For hanging installation, the mounting surface should be solid bricks, concrete or the equivalent
strength structure with sufficient loading capacity, otherwise you should take reinforce, bracing,
vibration reduction and other measures. The connecting between mounting surface and mounting
bracket, mounting bracket and air conditioner should be secure, stable and reliable, make sure the
air conditioner is installed without sliding, overturning and falling down.
7. Somewhere that has no leakage of flammable or corrosive gases.
8. lnstalled in the following places may cause malfunctions of the air conditioner. If it is unable to
avoid, please contact the service point.
1) Somewhere that has machine oil
2) Saline areas in the seaside
3) Somewhere that has sulfur-containing gases (such as sulfide hot spring)
4) Somewhere that has frequency conversion facilities, such as RF facilities, welder machines, medical
equipments, that radiates strong EMI.
5)Avoid installing to the side that has heavy sandstorm, smoking from factories, strong sea wind.
6) Special surrounding conditions.
9. Choose somewhere that there is no rain, no direct sunlight and also good ventilated place as far as
possible. If it is unable to avoid, you should make a shelter, but pay attention to the condenser heat
dissipation, it must not be hindered.
1 O. The installation location should be better not rearing animais or planting trees or flowers.
11. Please avoid the location that may has flammable or explosive gas leakage.
12. Convenient to install and operate, avoid strong wind, and also dry and good ventilated.
13. The main requirements of spatial position to install outdoor unit: Left � 30 cm, right � 60 cm, back �
30 cm, front�200 cm.
3.Preparation before installation
5

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Aw-fwdb024-n91

Table des Matières