TROUBLESHOOTING GUIDE

The troubleshooting indicator of the multidirectional joystick control displays
information codes to help you understand what is occurring with your Climb-N-Go.
LIGHT CODE
Light blinks
Anti-runaway
once
function fault
Light blinks
Hall Sensor fault
twice
(Left Motor)
Light blinks
Hall Sensor fault
three times
(Right Motor)
Light blinks
Under-voltage
four times
fault
Light blinks
Motor Phase fault
five times
(Left)
Light blinks
Motor Phase fault
six times
(Right)
Light blinks
Electromagnetic
seven times
clutch fault (Left)
Light blinks
Electromagnetic
eight times
clutch fault (Right)
Light blinks
Other fault
nine times
Light blinks
Communication
ten times
fault
12
MEANING
Check the joystick to make sure that it returns to the
center point position.
Check the connection of the left motor cables. Make
sure that the rods of the male connection are in good
condition, that nothing is disconnected or loose,
and that nothing is blocking the entry to the female
connection.
Check the connection of the right motor cables. Make
sure that the rods of the male connection are in good
condition, that nothing is disconnected or loose,
and that nothing is blocking the entry to the female
connection.
Check the battery voltage.
Check the connection of the left motor cables. Make
sure that the rods of the male connection are in good
condition, that nothing is disconnected or loose,
and that nothing is blocking the entry to the female
connection.
Check the connection of the right motor cables. Make
sure that the rods of the male connection are in good
condition, that nothing is disconnected or loose,
and that nothing is blocking the entry to the female
connection.
Flip left wheel locking lever.
Flip right wheel locking lever.
Check the cable of the multidirectional joystick control,
check whether the cable is damaged and whether it
needs to be replaced.
Check the data transmission between the multidirection-
al joystick control and the box.
SOLUTION