Control modes
DIP2/5−7
9
(local mode)
10
(terminals 0)
12
(terminals 2)
14
(terminals 11)
16
(terminals 16)
EDK84DGDVBxxx4 DE/EN/FR/ES/IT 9−0
DIP switch / potentiometer assignment 0
Description
W
(DIx
High)
The technology application is controlled locally via elements on the inverter and
the digital input terminals:
}
At mains connection the motor starts up automatically if RFR is bridged
or set!
DI1
Setpoint of P2 (speed)
DI2
Preset setpoint 2
DI3
Activate DC injection brake
DI4
Change of direction of rotation (not possible if DIP1/2 = on (set to the
left))
DI5
Release holding brake manually (operating mode after setting C02580)
The technology application is controlled via the digital input terminals of the
inverter:
DI1
Preset setpoint 1
DI2
Preset setpoint 2
DI3
Activate DC injection brake
DI4
Change of direction of rotation
DI5
Release holding brake manually (operating mode after setting C02580)
The technology application is controlled via the digital input terminals of the
inverter:
DI1
Preset setpoint 1
DI2
Preset setpoint 2
DI3
Quick stop
DI4
Change of direction of rotation
DI5
Release holding brake manually (operating mode after setting C02580)
The technology application is controlled via the digital input terminals of the
inverter:
DI1
Change of direction of rotation
DI2
Activate DC injection brake
DI3
Motor potentiometer: speed higher
DI4
Motor potentiometer: speed lower
DI5
Release holding brake manually (operating mode after setting C02580)
The technology application is controlled via the digital input terminals of the
inverter:
DI1
Preset setpoint 1
DI2
Preset setpoint 2
DI3
CW rotation/quick stop
DI4
CCW rotation/quick stop
DI5
Release holding brake manually (operating mode after setting C02580)
l
Settings
Preset setpoint 3
Preset setpoint 3
Preset setpoint 3
Preset setpoint 3
5
83