Press the OK key
Control unit software version
N. total manoeuvres (in tens)
N. manoeuvres since latest maintenance (in tens)
N. radio control devices memorised
end
logic
end
radio
end
lingua
end
default
end
autoset
end
l. s w adj
end
12 -
ARGO-ARGO G
param. 1
param. 2
param. . . .
logic. 1
logic. 2
logic. . . .
hidden button
add. start
Add. 2ch
hidden button
read
erase 64
PRG.
COD RX
1 A 9 C
v
OK
ITA
- +
FRA
OK
- +
DEU
OK
- +
ENG
OK
- +
esp
OK
PRG

LIMIT SWITCH ADJUSTMENT

ACCESS TO MENUS

See PARAMETERS MENU
See LOGIC MENU
release
desired button
release
desired button
T
01 t1
See RADIO MENU
+/-
OK
2 2 F D
OK
0 1
Logic
Description
PED
partial opening input activated
STRe
START input activated
STOP
STOP input activated
PHOT
PHOT input activated
BAR
SAFETY EDGE input activated
CLOS
CLOSE input activated
OPEN
OPEN input activated
Suo
opening limit switch activated
Suc
closing limit switch activated
reverse due to obstacle
A P
autoset function is running
Set
WARNING! Obstacle detection function is not active
ER01
photocell test error
safety edge test error
ER02
mosfet test error
ER10
shunt test error
ER11
(Fig. F)
encoder test error
ER21
thermal cutout error
ER40
ATTENTION: when the control unit shows this error, the motor cannot
perform any manoeuvres for a set time. During this time, power to the
device MUST NOT be disconnected otherwise the deactivation time will be
prolonged.
ER50
optional module communication error
35.40
Set torque threshold %
Maximum motor torque %
Scroll up
Cancel/return to main menu
Scroll down
Con rm/Switch on display
T
o 01
T
o 01
OK