Setting the detection
distance of the IR sensor
If flushes are actuated too soon, too late or
unintentionally, you can optimise the
detection distance of the IR sensor.
1
Disconnect the IR sensor.
✓ The LED lights up.
2
Wait until the LED goes out.
3
Connect the IR sensor.
✓ The LED flashes 3 times and
then lights up for 15 seconds.
✓ Within these 15 seconds, the IR
sensor can be covered and the
setting can be initiated.
4
Cover the IR sensor completely for
around 20 seconds.
18
5
Remove hand from the detection
range of the IR sensor until the LED
goes out, then flashes, and finally
lights up for 10 seconds.
✓ 1 flash: large detection range
set.
✓ 2 flashes: small detection range
set.
6
Actuate the flush to check the
detection range.
✓ LED flashes: small detection
range set.
✓ LED does not flash: large
detection range set.
7
If the incorrect detection range has
been set, restart the setting process
from Step 1.