Electrical Wiring; Ac Power Connection; Dc Power Connection - Tuthill FILL-RITE DEF DF Serie Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Electrical Wiring

Wiring Procedure
WARNING! Electrical wiring should be performed ONLY by a licensed electrician in compliance with local,
state, and national electrical code NEC/ANSI/NFPA 70, NFPA30, and NFPA 30A, as appropriate to the
intended use of the pump. The pump must be properly grounded. Improper installation or use of this pump
can result in serious bodily injury, or death!
CAUTION! All pumps should operate at the rated voltage. Power should be supplied to the pump from a 15
amp circuit breaker. No other equipment should be powered by this circuit. Wiring must be of sufficient size
to carry the correct current for the pump. Voltage drop will vary with distance to pump and size of wire; refer
to the National Electrical Code (NEC), or local codes, for voltage drop compensation to be sure you are using
the correct size wire for your application.
WARNING! Be certain the power switch is "OFF" prior to connecting to the power source (AC or DC) to
prevent unexpected starting of the motor. Unexpected motor start can cause unintended discharge of fluid,
creating a potential hazard.

AC Power Connection

WARNING! THIS PRODUCT MUST BE GROUNDED! DO NOT defeat the ground prong on the plug
by using an adapter, or otherwise modifying the plug. DO NOT plug this appliance into an ungrounded
receptacle.
AC pumps come pre-wired for 120 VAC, 60 Hz operation. These pumps are
equipped with a conventional 120 VAC 3-prong grounded plug that can be inserted
into any conventional grounded receptacle. For safety and proper operation, do
not remove or in any way bypass the ground prong.

DC Power Connection

Inspect power cable before each use! Damage to the outer
jacket of the cable that exposes wiring requires replacement
of the power cable.
The power cable terminates in black and red clamps.
1. Connect the black (negative) clamp to the negative post
of the DC power source first.
2. Connect the red (positive) clamp to the positive post last.
Clamps should be disconnected in reverse order.
Black
1
7
Red
2