It is the responsibility of the installer/owner to ascertain
compliance with specific local regulations prior to installa-
tion.
Jacuzzi Europe S.p.A. gives no guarantee in this respect
and refuses all responsibility regarding compliance of the
installation carried out.

Technical Features

The Premium spas feature a single-phase power supply (220-
240 V). All electro-mechanical parts and pipes are enclosed.
The J-210 is equipped with 1 two-speed pump, whilst the J-
235/245/275 are equipped with 2 pumps.
The J-315, J-325 model is equipped with 1 two-speed pump
for hydromassage, the J-335, J-345, J-355, J-365, J-375, J-385 , J-
575, J-585 and J-LXL models have 2 pumps; all models are also
equipped with a circulation pump.
The models of the J-400 range have 1-2-3 hydromassage
pumps and a circulation pump.
Maximum absorption of the system
The electrical system that powers the spa must absolutely be
sized for maximum consumption (as shown in the table).
Power supply
(single-phase)
Voltage
Hertz
J-210
220-240 ~
50
J-235
220-240 ~
50
J-245
220-240 ~
50
J-275
220-240 ~
50
J-315
220-240 ~
50
J-325
220-240 ~
50
J-335
220-240 ~
50
J-345
220-240 ~
50
J-355
220-240 ~
50
J-365
220-240 ~
50
J-375
220-240 ~
50
J-385
220-240 ~
50
J-LXL
220-240 ~
50
Power supply
(single-phase)
Voltage
Hertz
J-415
220-240 ~
50
J-465
220-240 ~
50
J-480
220-240 ~
50
J-495
220-240 ~
50
J-575
220-240 ~
50
J-585
220-240 ~
50
(k): 230 V (single-phase)
(j): max. power absorption
Tot. Consumption: electric hea-
ter + pump(s)
Ampere
kW
(k)
(j)
21
4,8
(k)
(j)
29
6,7
(k)
(j)
29
6,7
(k)
(j)
29
6,7
(k)
(j)
21
4,8
(k)
(j)
21
4,8
(k)
(j)
29
6,7
(k)
(j)
29
6,7
(k)
(j)
29
6,7
(k)
(j)
29
6,7
(k)
(j)
29
6,7
(k)
(j)
29
6,7
(k)
(j)
29
6,7
pump(s)
electric
heater
Ampere/kW
Ampere/kW
(k)
(j)
(k)
(j)
17
/3,8
12
/2,7
(k)
(j)
(k)
(j)
17
/3,8
12
/2,7
(k)
(j)
(k)
(j)
17
/3,8
12
/2,7
(k)
(j)
(k)
(j)
26
/6,0
12
/2,7
(k)
(j)
(k)
(j)
17
/3,8
12
/2,7
(k)
(j)
(k)
(j)
17
/3,8
12
/2,7
If sufficient electrical energy is not available, an electronic en-
ergy consumption limiter can be activated from inside the
electronics box.
This operation can only be performed by authorized Jacuzzi
technicians and limits electricity consumption as follows:
J-210
J-315/325
- alternative consumption: 3.4 kW (when the pump is run at
high speed, the electric heater goes off).
J-235/245/275
J-335/345/355/365/375/385/J-LXL
J-415/465/480/495
J-575/585
- medium alternative consumption: 4,8 kW (1 pump by opera-
ting in high speed + electric heater).
- minimum alternative consumption: 3.9 kW (2 pumps opera-
ting at high speed, the heater turns off).
Weights
net
average
weight
fill
kg
litres
J-210
~ 239
~ 908
J-235
~ 326
~ 1363
J-245
~ 375
~ 1363
J-275
~ 366
~ 1590
J-315
~ 259
~ 871
J-325
~ 312
~ 1363
J-335
~ 342
~ 1363
J-345
~ 374
~ 1401
J-355
~ 379
~ 1514
J-365
~ 394
~ 1666
J-375
~ 407
~ 1779
J-385
~ 415
~ 1893
J-LXL
~ 406
~ 1476
J-415
~ 265
~ 871
J-465
~ 411
~ 1552
J-480
~ 454
~ 1817
J-495
~ 517
~ 1968
J-575
~ 407
~ 1685
J-585
~ 407
~ 1666

User safety

I
The system, if installed by qualified personnel, does not present
any hazard for the user. Safety is however also contingent upon
proper use, as set forth by the user's manual included with the
product. The user must contact qualified personnel for special
operations described in the manual.
I
It is important to make sure that personnel tasked to install and
manage the system are qualified as per legal requirements in
effect in the country where installation is carried out.
31
maximum
total
support
load concentrated
water
max.
on support area
area
weight
volume
2
litres
kg
m
~ 1173
~ 1412
~ 2,48
~ 1741
~ 2066
~ 4,19
~ 1779
~ 2153
~ 4,19
~ 2006
~ 2371
~ 4,97
~ 1060
~ 1318
~ 2,52
~ 1666
~ 1976
~ 3,33
~ 1703
~ 2044
~ 3,67
~ 1741
~ 2114
~ 3,67
~ 1855
~ 2233
~ 3,89
~ 1893
~ 2285
~ 3,89
~ 2196
~ 2601
~ 4,36
~ 2196
~ 2610
~ 4,36
~ 1893
~ 2298
~ 3,69
~ 1098
~ 1362
~ 2,46
~ 1931
~ 2340
~ 3,72
~ 2271
~ 2724
~ 4,48
~ 2347
~ 2862
~ 5,28
~ 2063
~ 2470
~ 4,16
~ 2044
~ 2451
~ 4,16
®
2
kg/m
~ 569
~ 493
~ 513
~ 476
~ 522
~ 592
~ 555
~ 574
~ 573
~ 587
~ 596
~ 598
~ 621
~ 552
~ 628
~ 607
~ 542
~ 593
~ 589

Publicité