GYS STARTPACK PRO 12.24 Mode D'emploi page 10

Masquer les pouces Voir aussi pour STARTPACK PRO 12.24:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
Use in CHARGER mode (charge the internal batteries)
In order to have your STARTPACK PRO fully operational and to ensure maximum output
power, it is advised to charge it after each use, and leave it charging until its next use.
STARTPACK PRO 12.24 include a high quality automatic charger to unsupervised charge the 2
internal batteries to 100% and to maintain an optimum charge (Floating System).
• Turn the battery switch to OFF and disconnect the clamps from the vehicle.
• Plug the voltage connector on the 12V socket.
WARNING: If you do not plug the 12V socket, the charge won't start (the
leds will light for a short moment)
Connect the charger to a 230V 50/60Hz socket.
STARTPACK PRO 12.24 will indicate thecharge status:
After the charge, you can leave the device connected to the socket.
Internal Batteries: advice and maintenance
These high performance batteries require particular care. Following these instructions will
prolong their effective life to the maximum.
 Charge the product initially after purchase and then after each use.
 Do not use an external charger. Only use the one integrated in the product.
 Turn the battery-switch OFF during the charge, and disconnect the voltage selector to
prevent any error after a recharge.
 Never short-circuit the clamps when the battery-switch is turned ON.
 Never connect the red clamp on the (-) of the vehicle battery, and the red clamp on the
ground of the engine. This would result in a short circuit.
 Wait 3 minutes between each starting attempt. This allows the batteries voltage to rise
again, and the internal elements to cool down. If you do not wait and/or if any starting
attempt lasts for too long, you risk losing some power, and you reduce your chances of
succeeding the start on next attempts.
Orange light: charging – voltage increasing
Flashing Orange light: voltage regulation (2h to 16h if batteries are
sulphated or deeply discharged)
Green light : the battery is charged.