VIII. Special accessories
PWA2700
Note: An embrasure breadth of at least 88 cm is required for embedding into the wall on
both sides.
• When using the PWA2700, first remove the plastic plug from the door bar casing (if
necessary lever through the small hole with a screwdriver / Fig. 25).
• Insert the door bar end piece with round bolts and tighten with the screw of accessory
article PWA2700 (Fig. 26).
• Mount the wall strike plate onto the round bolts.
• Lock the door bar onto the wall until the end stop. Mark out the attachment point (1.) of
the wall strike plate. Close back the door bar (Fig. 28).
• Pre-drill the attachment points for the wall strike plate with Ø 6 mm, insert the dowel
and screw (Fig. 28).
• Drill through both of the external mounting holes (2.) with Ø 10 mm, and a depth of at
least 140 mm. Insert the complete dowel with the screw and tighten (Fig. 28).
• Drill out the holes for the connecting bolts (3.) with Ø 14–16 mm, with a depth of 70 mm
(Fig. 28). Press down the plastic cover.
Abb. 25
Fig. 25
2.
Fig. 27
86
Fig. 26
1.
Fig. 28
2.
1.
3.
3.
2.
1.
2.