Fig. 21
Fitting with or without plastic underlays
1. Hold the lock case with the defined plastic underlay onto the marked lock case position.
For flush doors and folding thicknesses < 5 mm on the mounting position, drill holes Ø 20 mm
6 mm deep so that the lock casings can be mounted flat. Drill through the two Ø 10 mm
mounting holes, min. 140 mm deep for 120 mm frame plugs.
Insert the screw in the dowel (Fig. 21), push both into the hole up to the dowel collar and
tighten the screw.
For special installation conditions, e.g. thicker walls, use dowels and screws with a length of
140 mm (available as special accessories from ABUS. In this case, drill the hole at least 160 mm
deep).
If the screws or the dowels cannot find a secure grip, we recommend all-through screw fittings
with PV1820 (Fig. 30) or the use of composite mortar from well-known brands in connection
with the enclosed screw (without dowel).
2. Press down the cover onto the lock cases (Fig. 24).
3. Press the cylinder escutcheon firmly onto the door exterior (Fig. 25).
4. The door bar can also be incorporated into the wall instead of fitting the lock case.
In this case, the cover for the hole in the wall PWA2700 (Fig. 26 - 29) can be used.
Fig. 22
76
Fig. 23
Fig. 24
VII. Operating instructions
1. Close the door initially with the existing closing safety device. Then activate the reinforced
door bar PR2800 as additional protection using the key. Close the door bar until the end
stop by turning the key once or twice.
2. The PR2800 must be retracted the other way around until the end stop before opening the
door.
3. The reinforced door bar PR2800 is maintenance-free and does not require any lubricant.
Do not use any aggressive or abrasive cleaning products when cleaning the surfaces.
VIII. ABUS special accessories
The following special accessories are commercially available to complement this security door bar for
various applications:
PWA2700: Wall strike plate, instead of the normal lock casing
• Note: An embrasure breadth of at least 86 cm is required for embedding into the wall on both
sides (doorway 90 cm).
• When using the PWA2700, first remove the plastic plug from the door bar casing (if necessary
lever through the small hole with a screwdriver / Fig. 26).
• Insert the door bar end piece with round bolts and tighten with the screw of accessory article
PWA2700 (Fig. 27).
• Mount the wall strike plate onto the round bolts.
• Lock the door bar onto the wall until the end stop. Mark out the attachment points (1.)
of the wall strike plate. Close back the door bar (Fig. 28).
• Pre-drill the attachment points for the wall strike plate with Ø 6 mm, insert the dowel
and screw (Fig. 29).
• Drill through both of the external mounting holes (2.) with Ø 10 mm, and a depth of at
least 160 mm. Insert screw into the dowel (fig. 21) and tighten the screw firmly (Fig. 29).
• Drill out the holes for the connecting bolts (3.) with Ø 14 - 16 mm, width a depth of
70 mm (Fig. 29). Press down the plastic cover.
Fig. 25
GB
77