ENGLISH
10
11
12
13
14
15
OPERATE THE UNIT BY CA8
When used in standalone or master/slave mode we strongly advise you to use the CA-
8 "Wired easy controller".
Connect the controller to the jack input of the first unit (master).
Now you can control all the connected units:
STANDBY BUTTON:
Press this button to start/stop blackout mode on all connected units.
MODE/FUNCTION BUTTONS:
With the MODE button you can select 3 different modes:
The LED is off: with the FUNCTION button you can select different strobe modes,
like "sound strobe".
The LED is blinking: with the FUNCTION button you can select different shows.
The LED is on: (music mode is temporarily switched off)
Press the FUNCTION button shortly: to change the colors
Press the FUNCTION button longer: to change the gobos
MAINTENANCE
Make sure the area below the installation place is free from unwanted persons during servicing.
Switch off the unit, unplug the mains cable and wait until the unit is cooled down.
During inspection the following points should be checked:
All screws used for installing the device and any of its parts should be tightly fastened and may not be
corroded.
Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any
deformation.
When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced.
BRITEQ
®
Prism
000 - 007 No Effect
008 - 255 Prism Effect
Prism Rotation
000 - 127 Index position
128 - 189 Prism turning counter clockwise (fast → slow)
190 - 193 No rotation
194 - 255 Prism turning clockwise (slow → fast)
Focus
000 - 255 Focus setting
Pan Fine (Least significant bit)
000 - 255
Tilt Fine (Least significant bit)
000 - 255
Special functions
000 - 069 No function
070 - 079 Activate blackout during pan/tilt (*)
080 - 089 Disable blackout during pan/tilt (*)
090 - 099 Activate blackout during color change (*)
100 - 109 Disable blackout during color change (*)
110 - 119 Activate blackout during gobo change (*)
120 - 129 Disable blackout during gobo change (*)
130 - 199 No function
200 - 209 Reset all (*)
210 - 249 No function
250 - 255 Sound activated automatic mode
14/79
OPERATION MANUAL
BT-70LS