S+S Regeltechnik AERASGARD RFTM-PS Serie Notice D'instruction page 11

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

G
®
AERASGARD
RPS - SD ⁄ RFTM - PS - xx
TECHNICAL DATA
Ambient temperature:
Permitted humidity:
Warm up time:
Response time:
Electrical connection:
Housing:
Dimensions:
Mounting:
Protection class:
IP rating:
Standards:
Optional:
®
AERASGARD
RPS - SD
RFTM - PS - W
RFTM - PS - CO2 - W
Type ⁄ WG02
RPS - SD
R P S - S D
RFTM - PS - W
R F T M - P S -W
R F T M - P S -W LCD
RFTM - PS - CO2 - W
R F T M - P S - C O 2 -W
R F T M - P S - C O 2 -W LCD
Outputs:
Equipment:
Note:
0...+ 50 °C
0...95 % r. H. (non-precipitating air)
approx. 1 hour
< 2 minutes
0.14 - 1.5 mm
2
, via screw terminals
plastic, material ABS, colour pure white (similar to RAL 9010)
98 x 98 x 33 mm (Baldur 2)
wall mounting or on in-wall flush box, Ø 55 mm, base with 4 holes, for attachment
to vertically or horizontally installed in-wall flush boxes for rear cable entry,
with predetermined breaking point for top/bottom cable entry for surface-mounted installation
III (according to EN 60 730)
IP 30 (according to EN 60 529)
CE conformity, electromagnetic compatibility according to EN 61 326,
EMC Directive 2014 ⁄ 30 ⁄ EU, Low Voltage Directive 2014 ⁄ 35 ⁄ EU
Display with illumination, 2-line, cutout approx. 36 x 15 mm (W x H),
to display the actual humidity, actual temperature, of the fine-dust and CO2 content
as well as for switch point display
Room sensor for fine dust (PM), Standard
Multifunctional room sensor
for humidity, temperature and fine dust (PM), Premium
Multifunctional room sensor
for humidity, temperature, fine dust (PM) and CO2 content, Deluxe
Measuring Range
Humidity
Temperature
0...100 % r.H.
0...+50 °C
0...100 % r.H.
0...+50 °C
0...100 % r.H.
0...+50 °C
0...100 % r.H.
0...+50 °C
0 -10 V or 4...20 mA (selectable via DIP switches, selected variant applies for all outputs) –
Standard room sensor RPS - SD with fixed output 0 -10 V!
W = changeover contact – Standard room sensor RPS - SD without changeover contact !
These units must not be used as safety-relevant devices!
PM
CO2
(switchable)
3
0... 50 µg/m
0...100 µg/m
3
0...300 µg/m
3
3
0...500 µg/m
(switchable)
(switchable)
0... 50 µg/m
3
3
0...100 µg/m
3
0...300 µg/m
0...500 µg/m
3
(4x as above)
3
0... 50 µg/m
0...2000 ppm ⁄
3
0...100 µg/m
0...5000 ppm
0...300 µg/m
3
3
0...500 µg/m
(4x as above)
0...2000 ppm ⁄
0...5000 ppm
11
Equipment
Item No.
Display
1501- 2110- 1001-000
W
1501- 2116- 7301-000
W
1501- 2116- 7321-000
W
1501- 2113- 7301-000
W
1501- 2113- 7321-000
Rev. 2021 - V11