Changing the filter unit
Important: Change the filter after 10,000
litres of water flow or if the water flow from
the filter drops off greatly.
However, the filter unit must be changed
after 6 months.
To do this, press the grey
-
ring down and pull on the
appropriate hose.
If you cannot pull the hose
-
or the nozzle out, spread the
pressure evenly across
the ring!
Insert new filter unit, check
-
that it is sealed.
8. Warranty
If a fault occurs during the warranty period, please
contact your contract partner, the installation com-
pany, quoting the unit type and production number
(see technical data or rating plate on the unit).
The warranty only applies if the instructions in this
fitting and operating manual have been adhered to
and followed.
10. Troubleshooting
Fault
No water
Low water flow rate
Screw fastenings are loose
000_EBA Woda-Pure.indd 13
9. Operator duties
Check the installation regularly to ensure it is
sealed.
The filter must be replaced by the operator if it is to
operate efficiently. The filter must be replaced regu-
larly depending on operating conditions if the water
pressure drops and no later than after 10,000 litres
of flow or every 6 months.
Drinking water is a food product.
Hygienic care should therefore be the rule when
work is being carried out.
Check seals:
daily
Replace filter:
not later than every 6 months
Replace stainless steel gauze hose:
every 5 years
In accordance with DIN 1988, wear and tear parts
must be replaced by specialist staff (specialist dealer
or customer service). Service is not required if the
filter cartridge is replaced regularly.
Cause
Water feed closed
Filter fitted incorrectly
System pressure is too low
Foreign particles accumulating in the
feed water
Poor sealing
Troubleshooting
Open inlet or shut-off valve in front or
behind the filter
Flow direction, check (arrow on date
ring)
Check system pressure
Premature change of the filter required
Check seals and replace if necessary
19.02.2009 10:04:11 Uhr
GB