Low ambient temperature. Wear warm
–
gloves to protect hands.
A firm grip impedes blood circulation.
–
Continuous operation is worse than an
–
operation interrupted by pauses.
In case of regular, long-term operation of
the device and in case of repeated occur-
rence of the symptoms (e.g. cold, numb fin-
gers) please consult a physician.
Replace the nozzle
Danger
Switch the appliance off prior to replacing
nozzle and activate hand spray gun until
device is pressureless.
Operating modes
1
4
0/OFF = Off
1 Operating with cold water
2 Operating with hot water
3 Eco setting (hot water max. 140 °F/60 °C)
4 Operating with steam
Turning on the Appliance
Set appliance switch to desired operat-
ing mode.
Indicator lamp for operational readiness
lights up.
The device starts briefly and turns off, as
soon as the working pressure is reached.
Release the trigger gun.
When activating the hand spray gun the de-
vice switches back on.
Note: If no water comes out of the high
pressure nozzle, vent pump. Refer to "Help
with malfunctions - appliance is not building
up pressure".
Adjust cleaning temperature
Set device switch to desired tempera-
ture.
86 °F/30 °C to 208 °F/98 °C:
Clean with hot water.
–
212 °F/100 °C to 302 °F/150 °C
Clean using steam.
–
Replace the high-pressure nozzle
(stainless steel) with steam nozzle
(brass), (refer to "Using steam").
Set working pressure and flow rate
Pressure/quantity regulation of the
pump unit
Turn the regulation spindle in a clock-
wise direction: Increase working pres-
sure (MAX).
2
Turn the regulation spindle in an anti-
3
clockwise direction: Reduce working
pressure (MIN).
Operation with detergent
For considerate treatment of the envi-
–
ronment use detergent economically.
The detergent must be suitable for the
–
surface to be cleaned.
With support of the detergent dose
valve set detergent concentration as
determined by the manufacturer.
Note: Recommended values at the control
panel at maximum working pressure.
Note: If detergent is be suctioned from an
external container, route the detergent suc-
tion hose through the recess to the outside.
Set pressure/temperature and deter-
gent concentration according to the sur-
face to be cleaned.
Note: To prevent damage due to too much
pressure, always position high pressure ray
first from a greater distance towards object
to be cleaned.
– 6
EN
Cleaning
13