EINHELL RG-EM 1742/1 Mode D'emploi D'origine page 19

Masquer les pouces Voir aussi pour RG-EM 1742/1:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 20
Anleitung_RG_EM_1742_1_SPK1:_
10. Troubleshooting
Fault
The motor fails to start
The motor performance
drops
Cutting is irregular
Important! For protection, the motor is equipped with a thermal switch which cuts out when the motor
is overloaded and switches on again automatically after a short cooling period.
30.10.2009
8:33 Uhr
Possible causes
a) The capacitor is defective
b) There is no electricity at the plug
c) The cable is defective
d) The connectors have become
separated from the motor or the
capacitor
e)
The mower is standing in high
grass
f) The mower housing is clogged
a) The grass is too high or too
damp
b) The mower housing is clogged
c) The blade is severely worn
a) The blade is worn
b) Wrong cutting height
Seite 19
Remedies
a) The mower housing is clogged. Have
repaired by the Customer Service
Center
b) Check the cable and the fuse
c) Check the cable
d) Have repaired by the Customer
Service Center
e) Start in low grass or on an area that
has already been mowed; change the
cutting height if necessary
f) Clean the housing so that the blade
moves freely
a) Correct the cutting height
b) Clean the housing
c) Replace the blade
a) Replace or resharpen the blade
b) Correct the cutting height
GB
19

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

34.004.90

Table des Matières