Adjusting pressure on compressor pump (Fireball 20T, 37T & 60T)
In order to alter the pressure on the compressor pump (on a working heater), use a
screwdriver to adjust the
pressure regulator (see
diagram). Clockwise = higher
pressure; anti-clockwise =
lower pressure.
To achieve the best result,
measure with a full tank. The
pressure is best if the cone
(flame deflector) is cherry red
and no flames are directed
outwards.
Flue gas tube with a rain cap (Fireball 20T CAP)
Affix a pipe (B) to the connection of the flue gas tube
(C). The pipe must be directed upwards. Never
position the pipe horizontally! An angle of max. 45°
is acceptable. The pipe must be at least one metre
long. Affix the rain cover (A) to the top of the pipe.
Be carefull!
Flames may never exit the air outlet. If there are
flames outside the outlet, pump pressure is too high.
Fireball 20T, 37T, 60T – please refer to instruction
manual for setting the pump pressure correctly.
Fireball 20 CAP – please contact your supplier.
Problems and Solutions
The heater burns but switches off after a short period
The light blinks, display shows E1
Incorrect pump pressure (Fireball
20T, 37T & 60T)
Dirty air filter (Fireball 20T, 37T &
60T)
Dirty fuel filter
Nozzle dirty
Photoelectric cell lens dirty
Photoelectric
cell
correctly
Photoelectric cell defective
Check pump pressure and adjust if
necessary
Clean/replace air filter
Clean/replace fuel filter
Clean/replace nozzle
Clean the lens
Install correctly
not
installed
Check and replace photoelectric cell
55