BE CAREFULL!
Flames may never exit the air outlet. If there are flames outside the outlet, pump
pressure is too high.
Adjust pump pressure (Fireball 20T, 37T & 60T):
In order to alter the pressure on the compressor pump (on a working heater), use a
screwdriver to adjust the pressure regulator (see diagram). Clockwise = higher
pressure; anti-clockwise = lower pressure.
To achieve the best result, measure with a full tank. The pressure is best if the cone
(flame deflector) is cherry red and no flames are directed outwards.
Adjust pump pressure (Fireball 20T CAP):
Please contact your supplier
ATTENTION!
Il ne doit jamais y avoir de flammes s'échappant de l'ouverture de la soufflerie. Si des
flammes surgissent de l'ouverture de la soufflerie, cela signifie que la pression de la
pompe est trop élevée.
Ajuster la pression de la pompe (Fireball 20T, 37T & 60T):
Pour adapter la pression de la pompe du compresseur, vous devez régler (dans le
cas d'un générateur d'air chaud qui fonctionne) le réglage de la pression à l'aide d'un
tournevis (voir illustration). Dans le sens des aiguilles d'une montre = pression plus
importante, dans le sens inverse des aiguilles d'une montre = pression moins
importante.
Pour atteindre le meilleur résultat pendant le test, il faut réaliser le test avec un
réservoir rempli. La pression est optimale lorsque le cône est rouge cerise et qu'il n'y
a pas de flammes vers l'extérieur.
Ajuster la pression de la pompe (Fireball 20T CAP) :
Veuillez contacter votre fournisseur