T80
3.3- TECHNICAL DATA
Tab. 1 shows the technical data of the actuator.
Input voltage
Maximum thrust and traction
single actuator
Maximum thrust and traction
pairs of actuators - 1motorised and 1 non-motorised
Maximum thrust and traction
three actuators - 1 motorised and 2 non-motorised
Maximum thrust and traction
1 motorised e 3 non-motorised
Maximum thrust and traction
2 motorised
Maximum thrust and traction
2 motorised e 2 non-motorised
Maximum thrust and traction
2 motorised e 3 non-motorised
Available strokes (mm)
Power input fully loaded (80Kg)
No-load translation speed
Duration of no-load stroke (s)
Duration of no-load stroke
Type of service
Operating temperature
Electrical protection class
Parallel connection of two or more actuators
Limit switch system
3.4- NOISE
The actuator has been designed and manufactured in order to reduce noise to a
minimum. The noise level of the actuator does not exceed 85 dB(A).
TECHNICAL DESCRIPTION -3
Tab.1
INSTALLATION AND USE INSTRUCTIONS
T80
230V ~ 50Hz
800N
750N
700N
650N
1200N
1200N
1200N
1200N
1100N
1100N
180 - 230 - 350 -
550 - 750 - 1000
0,30 A
1,35 A
12mm/s
(Stroke/no-load
translation speed)
YES
S
= 4min
2
- 5 + 55 °C
IP 55
YES
Electronic hall
effect
EN
24V
800N
750N
700N
650N
NO
29