Error messages
The error message automatically disappears after the error has been corrected.
Error message
Er1
Er3
Er4
Er5
Er6
Er7
Er8

Maintenance and cleaning

Cleaning the device
T I P
Recommendation regarding cleaning:
 Clean the unit as required but at least twice a year.
 When cleaning the pump, pay particular attention to the cleaning of the impeller unit and pump housing.
 In the event of the filter housing capacity reducing, clean the unit under running water using a brush.
 Do not not use cleaning agents or chemical solutions.
 Recommended cleaning agent for removing stubborn limescale deposits:
– Vinegar- and chlorine-free household cleaning agent.
 After cleaning, thoroughly rinse all parts in clean water.
Cleaning/replacing the impeller unit
How to proceed:
 G
1. Remove screws.
– The screws are used as transport protection and not required for operation.
2. Actuate the engagement hook and fold up the strainer top casing.
3. Remove pump.
4. Remove screws.
5. Remove the pump housing including its holding ring, sealing and impeller unit.
– Clean all components under running water using a soft brush, replace damage parts.
6. Reassemble the unit in the reverse order.
– Place the pump cable into the cable opening of the bottom strainer casing such that the cable will not be crushed
when closing the filter housing.
Cause
Missing connection to pump, cable
break
Excess temperature
Overcurrent
Pump blocked
Pump has run dry
Overvoltage
Undervoltage
Remedy
Pull power plug, wait for approx. 10 s. Then switch the pump on again.
 If the error message is still displayed, there is a cable break. Take the pump
to a specialist retailer for repair or send it to PfG.
 Check that impeller unit moves freely
 If the impeller unit is sluggish, the pump is requiring too much power
 The ambient temperature is too high
Check that impeller unit moves freely
 If the impeller unit is sluggish, the pump is requiring too much power
Check pump and remove obstacle
 Submerge pump in water
 For dry installation ensure adequate water supply
Connect the pump to the correct mains voltage
 The unit is not suitable for use with the existing mains voltage range
 Keep extension cable to the pump as short as possible.
 The voltage to the pump is too low due to the voltage drop in long cables.
 Use extension cable to the pump with greater conductor cross-section
 The voltage to the pump is too low due to the voltage drop in cables with
too small of a conductor cross-section.