Maintenance And Cleaning - Pontec PondoMax Eco 1500 Notice D'emploi

Masquer les pouces Voir aussi pour PondoMax Eco 1500:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
- EN -

Maintenance and cleaning

Cleaning the device
Recommendation regarding cleaning:
• Clean the unit as required but at least twice a year.
• When cleaning the pump, pay particular attention to the cleaning of the impeller unit and pump housing.
• In the event of the filter housing capacity reducing, clean the unit under running water using a brush.
• Do not not use cleaning agents or chemical solutions.
• Recommended cleaning agent for removing stubborn limescale deposits:
– Vinegar- and chlorine-free household cleaning agent.
• After cleaning, thoroughly rinse all parts in clean water.
PondoMax Eco 1500/2500
Cleaning/replacing the impeller unit
How to proceed:
 C
1. Remove screws.
– The screws are used as transport protection and not required for operation.
2. Actuate the engagement hook and fold up the strainer top casing.
3. Remove pump.
4. Unscrew the pump housing and pull out the impeller unit.
– Clean all components under running water using a soft brush, replace damage parts.
5. Reassemble the unit in the reverse order.
– Place the pump cable into the cable opening of the bottom strainer casing such that the cable will not be crushed
when closing the filter housing.
PondoMax Eco 3500
Cleaning/replacing the impeller unit
How to proceed:
 D
1. Remove screws.
– The screws are used as transport protection and not required for operation.
2. Actuate the engagement hook and fold up the strainer top casing.
3. Remove pump.
4. Unscrew the pump housing by turning counter-clockwise and remove (bayonet closing mechanism).
– Clean all components under running water using a soft brush, replace damage parts.
5. Reassemble the unit in the reverse order.
– Place the pump cable into the cable opening of the bottom strainer casing such that the cable will not be crushed
when closing the filter housing.
PondoMax Eco 5000/8000/11000/14000/17000
Cleaning/replacing the impeller unit
How to proceed:
 E
1. Remove screws.
– The screws are used as transport protection and not required for operation.
2. Actuate the engagement hook and fold up the strainer top casing.
3. Remove pump.
4. Remove screws.
5. Remove the pump housing including its holding ring, sealing and impeller unit.
– Clean all components under running water using a soft brush, replace damage parts.
6. Reassemble the unit in the reverse order.
– Place the pump cable into the cable opening of the bottom strainer casing such that the cable will not be crushed
when closing the filter housing.
12

Publicité

Table des Matières
loading

Table des Matières