Hydraulics
Two-way valve
IN
OUT
Frost protection
Capillary
sensor
Mounting
On the left side of the air curtain system there is an opening near the heating connection. Put
the capillary sensor through this opening in the air curtain and attach the sensor to the fan
housing with a plastic saddle clamp.
Optional: Magnetic valve MV / L
2/2-Danfoss valve
Type EV 220 B DN 15 – 50 NC
Min. pressure difference 0,1 bar
Distribution valve
IN
Air
direction
OUT
Frost protection
Type
EV 220B 15 B
EV 220B 20 B
EV 220B 25 B
EV 220B 32 B
EV 220B 42 B
EV 220B 50 B
The solenoid valve opens and closes the hot water circuit via
the summer / winter function of the control unit. If the air
curtain system is in summer or in standstill, the heating circuit
is closed to save energy.
The connection terminals are accessible from the top of the
air curtain system. They are located on the control board.
The clamps are covered with a metal plate. Bend the plate up-
wards on the indicated breaking line and break it off. Proceed
in accordance with the circuit diagram.
An additional connection option is available on the PCB.
These clamps are only accessible inside the air curtain system.
IN
Air
direction
OUT
Frost protection
Inner thread
1/2"
(request)
1/2"
(0699141)
3/4"
(0699142)
1"
(0699143)
1 1/4"
(request)
1 1/2"
(request)
Mixing valve
Air
direction
Plastic clamp
Kv-value
4,0
8,0
11,0
18,0
24,0
40,0
17
EN