Put protection on the floor and turn
the base on its back and screw the
4 adjustable legs tight to the base
[photo 5].
Preparation of the outside air
inlet kit (optional)
Using a hammer, remove the lower or
back plug from the base depending on
the configuration required [photo 6].
Do the same for the air inlet duct
depending on the configuration
required [photo 7].
Put the base into its definitive
position.
Feed the flexible tubing of the air inlet
into the hole in the base [photo 8].
Slide the clamp collar around the
flexible tubing. Insert the union into
the flexible tubing up to the stopper.
Using the size 7 key, screw the collar
to connect the unit [photo 9].
In case of back airflow, recover the
cap you removed from the base in
item [6], and put it on the precut
at the base's bottom (between the
channel and the base). This cap is
used as spacer [photo 10].
Put the air inlet duct into position.
Ensure the union, which fits into the
duct, is fully inserted [photo 11].
Attach the duct using the 4 M4 nuts
[photo 12].
Unless already done, put the base
on its feet. Put it into its definitive
position. Check the safety distance
from combustible materials. For the
distance at the front, refer to the
installation instructions for the Stûv
16-cube.
5
7
9
11
6
8
10
12
instruction - installation base Stûv 16-H - 0710