Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7. Adjustments

7.
Adjustments, Setup
To enter the configuration menu, you must proceed as follows:
A) Call up "CO-MEAS" menu item and confirm,
B) Then maintain key pressed as for switching off, but...
C) Release the key during the 2nd second of the switch-off function and press again
immediately.
Now you enter the configuration menu where you have three display fields.
7.1
First display filed: TAoffs (combustion air offset value)
Adjustment of the offset for the combustion air temperature
Important: new offset value for other temperature probe.
The adjustments of the offset value can be effected quickly. Pressing once will change
the cursor position to:
OK, cancel, +1, -1. +10, -10, etc.
Double-clicking at the number selected will change the offset value.
Double-clicking with cursor in position "OK" or "cancel" will change the display field. If
changes are to be stored, the display field will have to be quitted with double-clicking
on "OK".
7.2
Second display field: TFoffs (waste gas temperature offset value)
Adjustment effected as described above under 7.1. This offset value needs to be set
only if the waste gas temperature probe has been exchanged.
Manual Instruction
TAoffs:
10214
+1
-1
+10
-10
K
OK
STOP
TFoffs:
8582
+1
-1
+10
-10
K
OK
STOP
39
q
Fig. 15
Fig. 16