Parts and functions
Volume settings
!2"
!4"
!11"
!7"
!8"
!1" VR ACTIVE button
This is a button to approve/inhibit operations
of the GAIN volumes from !2" to !3" and the
BLACK volumes from !4" to !6".
When the power of the unit is on, it inhibits
operations.
The lamp is on when the approving/
operations are activated; otherwise, the
lamp is off.
!2" R GAIN volume
This adjusts the Rch gain.
The absolute value/relative value mode can
be switched in the GAIN-VR-MODE item of
the WHITE menu of the unit. When reading
card data and scene file data, this will be in
the relative value mode. The operations for
the B GAIN volume are the same.
!3" B GAIN volume
This adjusts the Bch gain.
(Continued)
!3"
!5"
!6"
!9"
!1"
!10"
!4" R BLACK volume
This adjusts the Rch black level.
Switching between the relative value mode
and the absolute value mode is executed in
the menu BLACK-VR-MODE of the unit.
When reading card data and scene file data,
this will be in the relative value mode.
It is possible to select either Flare or
Pedestal for item adjustment in the Menu
BLACK-VR-CONTROL item on the unit. The
operations for the G BLACK volume and B
BLACK volume are the same.
!5" G BLACK volume
This adjusts the Gch black level.
!6" B BLACK volume
This adjusts the Bch black level.
!7" M.PED volume
This adjusts the master pedestal level. The
adjustment range is between the minimum
value of –200 and the maximum value of
+200 with a center value of 0.
!8" IRIS display
This displays the iris of the camera.
!9" AUTO IRIS button
This turns on the auto iris function.
When the power is turned on, the unit is in
the state it was before turning off the power.
The lamp is on when the unit commands the
auto iris operation in the camera; otherwise,
the lamp is off.
!10" IRIS volume
This adjusts the iris of the camera.
When the AUTO IRIS button !9" is set to
OFF, it is possible to move the iris from
CLOSE to OPEN by turning this to the right.
!11" EXT alarm lamp
This lamp is on when the lens extender is
inserted.
E-12