Partial Recessed Installation - 2X4 Framing - Dimplex BLF3451 Manuel Du Propriétaire

Masquer les pouces Voir aussi pour BLF3451:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Fireplace Installation
Partial Recessed
Installation - 2x4 Framing
CAUTION: Two people may be
required for various steps of this
procedure.
1. Prepare a wall with a framed
opening of 30 ½ in. (77.5 cm)
wide x 16 ½ in. (42 cm) high
(Figure 7).
!
NOTE: The sizing has allowed
for ¼ in. (6.4 mm) around the
fireplace insert for ease of instal-
lation. This fireplace does not
require any additional venting.
!
NOTE: It is recommended that the
bottom of the unit not be mounted
higher than 40 in. (102 cm) from
the ground to maintain an opti-
mized viewing angle of the flame.
2. Choose your method of supplying
power to the unit:
• Plug in (you may run the power
cord out of the framed wall open-
ing to an existing outlet or install
an outlet on a nearby wall stud
within the wall).
• Hard wire the fireplace (recom-
mended). Follow the hard wiring
instructions on page 8.
WARNING: Do not attempt to wire
your own new outlets or circuits. To
reduce the risk of fire, electric shock
or injury to persons, always use a
licensed electrician.
12
WARNING: Ensure that the circuit
on which the fireplace is to be
installed has the power cut off at
the service panel until installation
is complete.
3. Lift fireplace and insert into open-
ing (Figure 8).
4. Use the supplied bubble level to
level the fireplace within the fram-
ing, adjust as required.
5. Drive four supplied mounting
screws through the four mounting
holes located in each corner of the
fireplace chassis, into wall studs
(Figure 8).
6. Refer to Front Glass Installa-
tion section for final installation
procedures.
Figure 7
2 x 4 Framing
www.dimplex.com

Publicité

Table des Matières
loading

Table des Matières