liminary assessment of the vibrational impact.
The declared vibration emission level repre-
sents the main applications of the power tool.
However, if the power tool is used for other
applications with different accessories or
poorly maintained, the vibration emission
may differ. This may significantly increase the
vibrational impact over the total working
period.
An estimation of the level of exposure to
vibration should also take into account the
Emission values for sound (Two-figure – specifications as per ISO 4871)
Sound emission
A-weighted emission pressure power level measured at the workplace
L
(re 20 μPa), in decibels
pA
K
Measuring uncertainty
Measured A-weighted sound power level
K
Measuring uncertainty
C-weighted peak sound pressure level measured at the workplace
L
, in decibels
pCpeak
K
Measuring uncertainty
Mean vibrational value (core drilling)
2
– m/s
2
– ft/s
K
Measuring uncertainty
2
– m/s
2
– ft/s
REMARK: The sum of the measured emission value and respective measuring inaccuracy
represents the upper limit of the values that can occur during measuring.
Wear hearing protection!
Measured values determined in accordance with the corresponding product standard.
Extension cable.
If the use of an extension cord
WARNING
is required, its length and con-
ductor cross-section must be adequate for the
application in order to prevent a voltage drop
in the extension cord, power loss and over-
heating of the power tool. Otherwise, the
extension cable and power tool are prone to
electrical danger, and the working efficiency is
decreased.
times when the tool is switched off or when
it is running but not actually doing the job.
This may significantly reduce the vibrational
load over the total working period.
Identify additional safety measures to protect
the operator from the effects of vibration
such as: Maintain the power tool and the
accessories, keep the hands warm, organiza-
tion of work patterns.
, in decibels
pA
L
(re 1 pW), in decibels
wA
, in decibels
wA
, in decibels
pCpeak
, in
en
7
JMU 404 M (**)
84.0
3
95.0
3
98.7
3
< 1.4
4.56
1.5
4.9

Publicité