-Appears when the
INSUFF
combustion air flow is below a
certain threshold.
DRAUGHT
-Occurs when the water
AL E
pressure does not come within
WATER
the values for correct
operation.
PRESSURE
-The system is stopped.
-Occurs when the gearmotor
AL b
works continuously and for
AUG TRIAC
more than 60 sec.
ERROR
-The system is stopped.
-Occurs in case of a water
AL c
temperature probe fault.
WATER
-The shutdown procedure is
PROBE
activated.
-Occurs when the water
AL d
temperature has exceeded the
HOT
fixed limits.
WATER
-The system is stopped.
-Occurs on relighting the stove
WAITING
immediately after having shut
COOL
it down.
AIR FLOW
-Occurs when the air flow
METER
meter is disconnected.
FAILURE
-Occurs when the water
FROST RISK
temperature falls below a
certain value.
Occurs when the stove has
SERVICE
exceeded 1800 hours of
DUE
operation or 2000 Kg pellet,
since the previous servicing.
The Manufacturer reserves the right to make technical or aesthetic changes to the products at any time without notice.
The drawings, measurements, diagrams and any other configurations are given only by way of example.
COLA S.r.l. – Viale del Lavoro, 7/9 – 37040 Arcole (VR) Italy – Tel. 045 7635780 – 045 6144043 – Cod. Fisc. – P.IVA e Iscr. Reg. Impr. 02990180230
Capitale Sociale Euro 52.000,00 i.v. – R.E.A. VR-301021 – Socio Unico – Fax Amministrazione 045 6100317 – Fax Commerciale 045 7639032
Fax Assistenza 045 7639030 – Fax Logistica 045 6144048 – e-mail: info@anselmocola.com – website: www.colastufe.com
-The combustion chamber is
dirty.
-The fume duct is obstructed.
-The fire door is not closed.
-The overpressure valves are
open-stuck.
-Faulty air flow meter.
-Occurs when the pressure
transducer on the water circuit
detects a pressure below 0,6
bar or above the fixed limits.
-The controller detects a faulty
gearmotor
(contacts stuck).
-Faulty probe
-The probe is disconnected
from the board.
-Occurs when the temperature
probe in the heating chamber
detects a value above 92°C.
-Reset attempt in shutdown
stage with stove hot in cooling
stage.
-The controller does not detect
the quantity of combustion air
and does not shut down the
stove; it only excludes the air
flow meter functions.
-The stove control detects the
water temperature below 6°C
and displays a message.
-Extraordinary
notice.
Direzione e coordinamento della Ferroli S.p.A
61
-Check cleanness of the fume
duct
chamber.
-Check hermetic closing of the
door.
-Check
overpressure valves.
-Other reinstatement
operations must be carried out
by a service centre.
-Check the cause of the
problem, restoring the circuit
pressure by bringing it to the
normal operating value.
-Reinstatement operations
must be carried out by a
control
relay
service centre.
-Reinstatement operations
must be carried out by a
service centre.
-Check the cause of the
problem, restoring the
temperature by bringing it to
the normal operating value.
-Alarm reset is possible only
after shutdown.
-Reinstatement operations
must be carried out by a
service centre.
-The pump starts in order to
move the water inside the
heating circuit.
- Monitor the water
temperature so that it does not
fall below 0°C.
- Cleaning - extraordinary
maintenance and
maintenance
reinstatement operations must
be carried out by a service
centre.
and
combustion
closing
of
the
ROCK