INSTALLATION
Hardwired installation
The rear/bottom aperture has a diameter of 1 1/4"
(3.25cm), therefore a 1" conduit fitting is recommended.
For rear wiring installation, draw the power supply
wiring through the hole in the wall and then through the
rear port of the wallplate before mounting the wallplate.
Removing the NEMA
14-50P cable
40A NEMA Model only
1.
To disconnect the NEMA power cable wiring,
unscrew the terminal screws as shown in the
diagram on the left.
2.
Loosen the left cable gland in a counter-
clockwise direction and pull down on the NEMA
cable to release it from your charger.
Safely store or dispose of the NEMA cable.
For rear wiring installations
Use a small screwdriver to cut a slit in the rubber
grommet to create an opening for your power
supply wiring. Alternately, if you are using conduit
for the rear attachment, remove the grommet and
attach the conduit fitting.
• For 40A model rear wiring installations, remove
the bottom cable gland and attach the provided
screw plug to cover the bottom port.
For bottom wiring installations
Remove the attached cable gland (40A model) or
screw plug (48A model) to allow the attachment of
the conduit fitting.
Installing the wallplate
1.
Remove the tape from the wallplate to detach
it from the charger.
2.
Place the wallplate with the center holes
aligned with the vertical line drawn earlier.
Mark the location of the holes.
For rear wiring installation, also mark
the location of the rear power entry port.
3.
Drill two holes with an appropriate sized bit.
Place the wallplate in alignment with the holes
and firmly mount the wallplate using the provided
wall screws. Do not over-tighten the screws.
• If you are mounting your charger on a solid
wall, use the wall anchors provided with your
charger.
EN
x2
x2
13