Table Of Display; Display Page Navigation - LOVATO ELECTRIC DMG800 Manuel D'application

Masquer les pouces Voir aussi pour DMG800:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

DISPL Y P GE N VIG TION
Phase-Phase voltages
IN = Instantaneous value
HI = Highest value
Phase voltages
IN = Instantaneous value
HI = Highest value
Phase-Neutral currents
IN = Instantaneous value
HI = Highest value
(continues)
T BLE OF DISPL Y P GES
Selection with s and t
P GE
1
PH SE-TO-PH SE VOLT GES - V(L1-L2), V(L2-L3), V(L3-L1), V(LL)EQV
2
PH SE-TO-NEUTR L VOLT GES - V(L1-N), V(L2-N), V(L3-N), V(L-N)EQV
3
PH SE ND NEUTR L CURRENTS - I(L1), I(L2), I(L3), I(N)
4
CTIVE POWER - P(L1), P(L2), P(L3), P(TOT)
5
RE CTIVE POWER - Q(L1), Q(L2), Q(L3), Q(TOT)
6
PP RENT POWER - S(L1), S(L2), S(L3), S(TOT)
7
POWER F CTOR - PF(L1), PF(L2), PF(L3), PF(EQ)
8
FREQUENCY- SYMMETRY - F, SY(VLL), SY(VLN), SY(I)
9
PH-PH VOLT GE H RMONIC DISTORTION - THD-V(L1-L2), THD-V(L2-L3), THD-V(L3-L1)
10
PH-PH VOLT GE H RMONIC N LYSIS - H2...31 V(L1-L2)-V(L2-L3)-V(L3-L1)
10
PH-N VOLT GE H RMONIC DISTORTION - THD-V(L1), THD-V(L2), THD-V(L3)
11
PH-PH VOLT GE W VEFORMS
12
PH-N VOLT GE H RMONIC DISTORTION - THD-V(L1),THD-V(L2),THD-V(L3)
13
PH-N VOLT GE H RMONIC N LYSIS - H2...31 V(L1)-V(L2)-V(L3)
14
PH-N VOLT GE W VEFORMS
15
CURRENT H RMONIC DISTORTION - THD-I(L1), THD-I(L2) THD-I(L3)
16
CURRENT H RMONIC N LYSIS - H2...31 I(L1)-I(L2)-I(L3)
17
CURRENT W VEFORMS
18
ENERGY METERS - kWh+(TOT), kWh-(TOT), kvarh+(TOT), kvarh-(TOT), kV (TOT)
19
ENERGY T RIFFS
20
TREND GR PH
21
HOUR COUNTER - Hr(TOT), Hr(Partial)
22
EXP NSION MODULES
23
COUNTERS
24
N LOG INPUTS
25
N LOG OUTPUTS
26
LIMIT THRESHOLDS
27
BOOLE N LOGIC
28
L RMS
29
INFO-REVISION-SERI L NO. - MODEL, REV SW, REV HW, Nº SERIES /
INTERN L TEMPER TURE
30
LOGO
31
(USER-DEFINED P GE 1)
32
(USER-DEFINED P GE 2)
33
(USER-DEFINED P GE 3)
34
(USER-DEFINED P GE 4)
NOTE: Some of the pages listed above may not be available if the function that they must view is not enabled.
For instance, if no alarms have been defined, then the larm page will not be shown.
LO = Lowest value
LO = Lowest value
LO = Lowest value
HI
LO
HI
LO
HI
LO
HI
LO
HI
LO
HI
LO
HI
LO
HI
LO
HI
LO
HI
LO
L1-L2
L2-L3
HI
LO
L1-N
L2-N
HI
LO
L1
L2
T R1
CNT1
IN1
OU1
LIM1
BOO1
L 1
V = verage value
GR = Graphic bars
V = verage value
GR = Graphic bars
V = verage value
MD = Max demand
Selection with
SUB P GES
V
GR
G
V
GR
B
V
MD
GR
V
MD
GR
V
MD
GR
V
MD
GR
V
GR
V
V
GR
V
GR
L3-L1
V
GR
L3-N
V
GR
L3
P RTI L
...
T R4
...
CNT4
...
IN8
...
OU8
...
LIM8
...
BOO8
...
L 8
3

Publicité

Table des Matières
loading

Table des Matières